58 • Schlage • Schlage Utility Soware User's Guide
Error CodesTroubleshooting
Error Codes
No. Error Solution
E304 Retrieving lock properties failed The HHD was disconnected from the lock before the
Retrieving Properties process was complete. The HHD
must remain connected to the lock until the process is
complete.
E305 Retrieving PIB properties failed The HHD was disconnected from the PIB300 before
the Retrieving Properties process was complete. The
HHD must remain connected to the PIB300 until the
process is complete.
E306 Retrieving PIM properties failed The HHD was disconnected from the PIM400/401 or
Legacy PIM before the Retrieving Properties process
was complete. The HHD must remain connected to
the PIM400/401 or Legacy PIM until the process is
complete.
E307 Retrieving door properties failed The HHD was disconnected from the Door before the
Retrieving Properties process was complete. The HHD
must remain connected to the Door until the process is
complete.
E400 Data files for French language are
missing
When attempting to change the language to French,
the French language files cannot be found. Contact
customer support.
E401 Data files for Spanish language are
missing
When attempting to change the language to Spanish,
the Spanish language files cannot be found. Contact
customer support.
E500 Relock Delay and Prop Delay should be
greater than Zero
The relock delay and prop delay must be greater than
zero (0). Change the delay(s) to a value greater than
zero (0).
E501 None of the properties are changed The Save menu item was tapped but no values were
changed. Change at least one value, or tap back to
cancel.
E502 Saving properties failed The HHD was disconnected from the lock before the
saving properties function was complete. The HHD
must remain connected to the lock until the saving
properties process is complete. OR
No valid programming credential was presented to
the lock. A valid programming credential must be
presented before the properties can be saved.
E503 The Unique ID should be in range 0 -
65535
The PIM400 or Legacy PIM address entered was
greater than 65535. Enter a value less than 65535 and
try again.
E504 The Unique ID should be in range
1-65534
The PIM400 or Legacy PIM address is incorrect. Enter a
value less than 65535 and try again.
E505 The RS485 address should be in range
0- 254
The RS485 address entered was greater than 254.
Enter a value less than 254 and try again.
E506 The Relock Delay value should be in
range 0- 255
The Relock Delay entered was greater than 255. Enter a
value less than 255 and try again.
E507 Reserved address 170 cannot not be
used for RS485 address
The RS485 address entered is incorrect. Enter a value
less than 254 and different than 170.
E508 Difference between high door and low
door cannot be equal or greater than 16
While setting the addresses of the Low and High doors
make sure that the difference between both is less
than 16.
E509 High door cannot be lesser than low
address
The address of the High door MUST be greater than the
Low door.