30 • Schlage • Schlage Utility Soware User's Guide
Lock PropertiesAD-Series Locks and Controllers
AD-400 (Networked Locks)
EDIT Tab
Property Description Default
Heartbeat The heartbeat is a brief communication from the lock to the PIM400. It allows an
idle lock to check for messages. Range: 15 seconds - many hours.
The value indicates the time between the heartbeats. Set to a shorter time (lower
number) for more frequent communication. Set to a longer time (higher number)
for less frequent communication. A smaller value will decrease battery life. A larger
value will increase battery life.
10 minutes
Comm Loss Fail Mode Lock state set when RF communication with the linked PIM400 fails.
States: As-Is, Secure/Lock, Unsecure/Unlock
As-Is
Allow Extended Unlocks
(Locks linked to
PIM400-TD2 only)
Extended unlock permits the lock to stay in an indefinite unlock state.
Enabling the Extended Unlock feature is required to implement a scheduled unlock
period from an ACP.
Enabled
Report RTX for Host to
unlock
1
Determines how an AD-400 will handle a request to exit.
If disabled, the AD-400 will only report that a request to exit has occurred. Disable
if the access point does not need to be electronically unlocked to provide egress
(if equipped with a crash bar) but the access control panel needs to be notified so
that a forced door does not occur.
If enabled, the AD-400 will report that a request to exit has occurred, and also will
query the PIM400 to determine if the AD-400 should be electronically unlocked.
Use this mode if the AD-400 needs to be electronically unlocked in order to provide
egress.
Disabled
Relatch Aer:
Timer/Door Status
Re-latch on:
• Timer Only (Lock when Timer expires (default 3 seconds) regardless of Door
status or Position)
• On Door Open or Timer (Lock when the Door opens or Timer expires)
• On Door Close or Timer (Lock when the Door closes or Timer expires)
Timer only
High Low Output
(Locks linked to
PIM400-TD2 only)
Polarity of the Request-to-Exit (RTX) signal. Low: RTX
Polarity of the Request-to-Enter (RTE) signal. Low: RTE
Polarity of the On Door Open, (Door Position Switch (DPS)) signal. High: open
Polarity of Trouble signal. Low: trouble
First, Delay, Retry First: First query a Lock makes to a PIM400 occurs immediately following
presentation of a credential. First is the amount of time, in milliseconds, an AD-
400 should wait before making its second query to a PIM400. This setting should
be slightly greater than the fastest response time from the access control panel or
host. This optimizes battery life and system performance.
Delay: The idle time between subsequent queries. Shorter delays may reduce
latency. Longer delays may enhance battery life.
Retry: The maximum number of times an access point queries a PIM400 before
the Lock goes back to sleep. The number of retries should be slightly greater than
the longest response time from the access control panel or host. Retrys = [{Max
Response Time of Panel- First}/Delay] +1
First: 300
msec.
Delay: 200
msec.
Retry: 5
Degraded (Cache)
Mode: Card Bit Format
Enter the number of bits in the credential card number.
0 = Degraded (Cache) mode disabled
0
1. These properties are view-only when the HHD is connected to the lock. Connect the HHD to the PIM400 to make changes.