Test Report ------------------------------------------------------------------------------ 44/47
Report No.: A5415648, FCC Part 15
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
IX. Section 15.247(d): Power Spectral Density
9.1 Test Condition & Setup
The tests below are running with the EUT transmitter set at high power in TDD mode. The
EUT is needed to force selection of output power le vel and channel number. While testing, the EUT
was set to transmit continuously and to be tested by the contact manner with the spectrum analyzer.
9.2 Test Instruments Configuration
P.S.: Notebook computer to control the EUT at maximal power output and channel
Number and set antenna kit
9.3 List of Test Instruments
Instrument Name Model No. Brand Serial No. Last time Next time
Spectrum Analyzer MS2665C ANRITSU 6200175476 09/11/02 09/11/03
9.4 Test Result of Power spectral density
The following table shows a summary of the test results of the Power Spectral Density.
Channel
Frequency
(GHz)
Ppr
(dBm)
Cable Loss
(dB)
Ppq
(dBm)
Limit
(dB)
Margin
(dB)
CH 01 2.412 -12.29 0.70 -11.59 8.00 -19.59
CH 06 2.437 -12.85 0.70 -12.15 8.00 -20.15
CH 11 2.462 -12.98 0.70 -12.28 8.00 -20.28
Note:
1. The following pages show the results of spectrum reading.
2. Ppr: spectrum read power density (using peak search mode),
Ppq: actual peak power density in the spread spectrum band.
3. Ppq = Ppr + |Cable Loss|