Asus WL-500b Specifikace Strana 39

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 203
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 38
Test Report ------------------------------------------------------------------------------ 29/47
Report No.: A5415648, FCC Part 15
Training Research Co., Ltd., TEL: 886-2-26935155, Fax: 886-2-26934440
VIII. Section 15.247 (C): Spurious Emissions (Radiated)
8.1 Test Condition & Setup
We’ d performed the test by the radiated emission skill: The EUT was placed in an anechoic
chamber, and set the EUT transmitting continuously and scanned at 3-meter distance to determine its
emission characteristics. The physical arrangement of the EUT was varied (within the scope of
arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in
amplitude, directivity, and frequency. The exact system configuration, which produced the highest
emissions was noted so it could be reproduced later during the final tests. For the measurement above
1GHz, according to the guidance we’ d set the spectrum analyzer’ s 6dB bandwidth RBW to 1MHz.
This was done to ensure that the final measurements would demonstrate the worst-case
interference potential of the EUT.
Final radiation measurements were made on a three-meter, anechoic chamber. The EUT
system was placed on a nonconductive turntable, which is 0.8 meters height, top surface 1.0 x 1.5
meter.
The spectrum was examined from 30 MHz to 1000 MHz using an Hewlett Packard 85460A
EMI Receiver, M.E. whole range Bi-log antenna (Model No.: VULB9160) is used to measure
frequency from 30 MHz to 1GHz. The final test is used the HP 85460A spectrum and 8564E spectrum
was examined from 1GHz to 25GHz using an Hewlett Packard Spectrum Analyzer, EMCO/CMT
Horn Antenna (Model 3115 / RA42-K-F-4B-C) for 1G - 25GHz.
At each frequency, the EUT was rotated 360 degrees, and the antenna was raised and lowered
from one to four meters to find the maximum emission levels. Measurements were taken using both
horizontal and vertical antenna polarization.
Appropriate preamplifiers were used for improving sensitivity and precautions were taken to
avoid overloading or desensitizing the spectrum analyzer. There are two spectrum analyzers use on this
testing, HP 85460A for frequency 30MHz to 1000MHz, and 8564E for frequency 1GHz to 25GHz. No
post-detector video filters were used in the test. The spectrum analyzer's 6dB bandwidth was set to
120KHz (spectrum was examined from 30 MHz to 1000 MHz), the spectrum analyzer's 6 dB
bandwidth was set to 1 MHz (spectrum was examined from 1GHz to 25GHz) and the analyzer was
operated in the maximum hold mode. There is a test condition applies in this test item, the test
procedure description as the following:
Three channels were tested, one in the top (CH01), one in the middle (CH06) and the other in
bottom (CH11). The setting up procedure is recorded on <1.3>
Zobrazit stránku 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 202 203

Komentáře k této Příručce