LSISAS RAID cardPIKE 2208User Guide
1-2 Chapter 1: Product introduction1.1 Welcome!Thank you for buying an ASUS® PIKE 2208 SAS RAID card!The ASUS PIKE 2208 allows you to create RAID 0,
ASUS PIKE 2208 1-31.3 Card layoutThe illustration below shows the major components of the RAID card.Front1. CacheVault connector2. ASUS PIKE interf
1-4 Chapter 1: Product introduction11. 1GB DDR3 SDRAMRear1.4 System requirementsBefore you install the PIKE 2208 SAS RAID card, check if the system
ASUS PIKE 2208 1-51. Locate the PIKE RAID card slot on the motherboard then remove the screws beside PIKE1 connector as shown.2. Align the golden n
1-6 Chapter 1: Product introduction
2Chapter 2: RAID congurationThis chapter provides instructions on setting up, creating, and conguring RAID sets using the available utilities.
2-2 Chapter 2: RAID conguration2.1 Setting up RAIDThe RAID card supports RAID 0, 1, 10, 5, 50, 6, and 60.2.1.1 RAID denitionsRAID 0 (Data striping
ASUS PIKE 2208 2-3• Having RAID 0 and RAID 5 virtual disks in the same physical array is notHaving RAID 0 and RAID 5 virtual disks in the same physic
2-4 Chapter 2: RAID conguration2.2 LSI WebBIOS Conguration UtilityThe LSI WebBIOS Conguration Utility (CU) is an integrated RAID solution that all
ASUS PIKE 2208 2-53. The Adapter Selection screen appears. If the system has multiple SAS adapters, select an adapter.4. Click Start to continue. Th
iiE7568First Edition (V1)August 2012Copyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and soft
2-6 Chapter 2: RAID congurationWebBIOS CU Toolbar IconsIcon DescriptionClick this icon to return to the main screen from any other WebBIOS CU screen.
ASUS PIKE 2208 2-7Here is a description of the options listed on the left of the main WebBIOS CU screen:• Advanced Software Option: Select this to al
2-8 Chapter 2: RAID conguration2.2.3 Creating a Storage CongurationThis section explains how to use the WebBIOS CU Conguration Wizard to congure
ASUS PIKE 2208 2-9 If you select Automatic Conguration, you can choose the redundancy mode: • Redundancy when possible: Automatically creates an
2-10 Chapter 2: RAID conguration2. Click Add To Array to move the drives to a proposed drive group conguration in the Drive Groups panel on the rig
ASUS PIKE 2208 2-11 ◊ Always Read Ahead: This enables read ahead capability, which allows the controller to read sequentially ahead of requested dat
2-12 Chapter 2: RAID conguration9. Click Yes to conrm the write policy mode you have chosen.10. Click Next after you nish dening virtual drives.
ASUS PIKE 2208 2-134. When you have nished selecting drives for the drive group, click Accept DG.5. Click Next. The Span Denition screen appears.
2-14 Chapter 2: RAID conguration ◊ Direct: In direct I/O mode, reads are not buffered in cache memory. Data is transferred to the cache and the hos
ASUS PIKE 2208 2-15Using Manual Conguration: RAID 10RAID 10, a combination of RAID 1 and RAID 0, has mirrored drives. It breaks up data into smaller
iiiContentsNotices ... vAbout this guide ...
2-16 Chapter 2: RAID conguration12. Select a second drive group from the Array With Free Space drop-down list, and click Add to SPAN. Both drive gr
ASUS PIKE 2208 2-17 ◊ Always Write Back: In Writeback mode, the controller sends a data transfer completion signal to the host when the controller c
2-18 Chapter 2: RAID conguration23. After the virtual drive is successfully created, the Manage SSD Caching screen appears. Click Cancel to close th
ASUS PIKE 2208 2-19 Here are brief explanations of the virtual disk options:• RAID Level: The drop-down menu lists the possible RAID levels for the
2-20 Chapter 2: RAID conguration• Disable BGI: Specify the background initialization status: ◊ No: Leave background initialization enabled. This m
ASUS PIKE 2208 2-21Using Manual Conguration: RAID 50RAID 50 provides the features of both RAID 0 and RAID 5. RAID 50 uses both distributed parity and
2-22 Chapter 2: RAID conguration13. If there are additional drive groups with three or more drives each, you can add them to the virtual drive.14.
ASUS PIKE 2208 2-23• Drive Cache: Specify the drive cache policy: ◊ Unchanged: Leave the current drive cache policy unchanged. This is the default.
2-24 Chapter 2: RAID congurationUsing Manual Conguration: RAID 6RAID 6 is similar to RAID 5 (drive striping and distributed parity), except that ins
ASUS PIKE 2208 2-25• Access Policy: Select the type of data access that is allowed for this virtual drive: ◊ RW: Allow read/write access. This is th
iv3.3 Windows® Server 2008 OS Driver Installation ... 3-93.3.1 During Windows® Server 2008 OS installation ...
2-26 Chapter 2: RAID conguration• Select Size: Specify the size of the virtual drive in terabytes, gigabytes, megabytes, or kilobytes. Normally, thi
ASUS PIKE 2208 2-27When you select Manual Conguration and click Next, the Drive Group Denition screen appears. You use this screen to select drives
2-28 Chapter 2: RAID conguration• Strip Size: The strip size species the size of the segment written to each disk in a RAID conguration. You can s
ASUS PIKE 2208 2-29 ◊ No: Leave background initialization enabled. This means that a new conguration can be initialized in the background while you
2-30 Chapter 2: RAID conguration2.2.4 Viewing and Changing Device PropertiesThis section explains how you can use the WebBIOS CU to view and change
ASUS PIKE 2208 2-31Controller Properties Menu OptionsOption DescriptionBattery BackupThis entry indicates whether the selected controller has a BBU. I
2-32 Chapter 2: RAID congurationController Properties Menu Options (Cont.)Option DescriptionPatrol Read RateUse this option to select the rate for pa
ASUS PIKE 2208 2-33Viewing and Changing Virtual Drive PropertiesTo access the Virtual Drive screen, click a virtual drive icon in the right panel on t
2-34 Chapter 2: RAID conguration• Select CC to run a consistency check on this virtual drive.Before you change a virtual drive conguration, back up
ASUS PIKE 2208 2-35Viewing Drive PropertiesThe Physical Drive screen displays the properties of a selected drive and also enables you to perform opera
vAbout this guideThis user guide contains the information you need when installing and conguring the server management board.How this guide is organi
2-36 Chapter 2: RAID congurationIf the drive state is Uncongured Good, four additional operations appear on this screen:• Select Make Global HSP to
ASUS PIKE 2208 2-372.2.5 Viewing System Event InformationThe SAS controller rmware monitors the activity and performance of all storage conguration
2-38 Chapter 2: RAID conguration2.2.6 Managing CongurationsThis section includes information about maintaining and managing storage congurations.R
ASUS PIKE 2208 2-39Importing or Clearing a Foreign CongurationA foreign conguration is a storage conguration that already exists on a replacement s
2-40 Chapter 2: RAID conguration3. Perform one of the following steps: • Click Preview to preview the foreign congurations. The Foreign Congura
ASUS PIKE 2208 2-412. Scenario #2: If some of the drives in a conguration are removed and re-inserted, the controller considers the drives to have f
2-42 Chapter 2: RAID conguration2.3 MegaRAID Storage ManagerMegaRAID Storage Manager software enables you to congure, monitor, and maintain storage
ASUS PIKE 2208 2-435. Enter your user name and organization name. In the bottom part of the screen, select an installation option:– If you select Al
2-44 Chapter 2: RAID conguration8. Select one of the Setup options. The options are fully explained in the screen text.– Normally, you would select
ASUS PIKE 2208 2-4511. Click Next to proceed.12. Click Install to install the program.13. When the nal Conguration Wizard screen appears, click F
viTypographyBold text Indicates a menu or an item to select.Italics Used to emphasize a word or a phrase.<Key> Keys enclosed in the less-t
2-46 Chapter 2: RAID conguration2.3.3 Installing MegaRAID Storage Manager Software for LinuxFollow these steps if you need to install MegaRAID Stor
ASUS PIKE 2208 2-472.3.4 Linux Error MessagesThe following messages may appear while you are installing MegaRAID Storage Manager software on a Linux
2-48 Chapter 2: RAID conguration2.3.5 Starting the MegaRAID Storage Manager SoftwareFollow these steps to start the MegaRAID Storage Manager softwar
ASUS PIKE 2208 2-494. Select an access mode from the drop-down menu.– Select Full Access if you need to both view the current conguration and chang
2-50 Chapter 2: RAID conguration2.3.6 MegaRAID Storage Manager WindowAfter you log in, the dashboard view provides an overview of the system and cov
ASUS PIKE 2208 2-51The following icons in the left panel represent the controllers, drives, and other devices:• System • Controller • Slot for a dr
2-52 Chapter 2: RAID congurationProperties View PanelThe right panel of the MegaRAID Storage Manager window has the Properties tab that displays info
ASUS PIKE 2208 2-53Help MenuOn the Help menu you can select Help > Contents to view the MegaRAID Storage Manager online help le. You can select He
2-54 Chapter 2: RAID conguration
3Chapter 3: Driver installationThis chapter provides instructions for installing the RAID drivers on different operating systems.
viiPIKE 2208 specications summary* The OS support depends on the motherboard’s OS support list.** Specications are subject to change without notice.
3-2 Chapter 3: Driver installation3.1 RAID driver installationAfter creating the RAID sets for your server system, you are now ready to install an op
ASUS PIKE 2208 3-37. Place a blank, high-density oppy disk to the oppy disk drive.8. Press <Enter>.9. Follow screen instructions to create
3-4 Chapter 3: Driver installation3.2 Windows® Server 2003 OS Driver Installation3.2.1 During Windows® Server 2003 OS installationTo install the RA
ASUS PIKE 2208 3-54. Insert the RAID driver disk you created earlier to the oppy disk drive, then press <Enter>.Windows SetupENTER=Continue
3-6 Chapter 3: Driver installation3.2.2 After Windows® Server 2003 OS installationTo update the RAID card driver after installing Windows® Server 200
ASUS PIKE 2208 3-75. Toggle No, Not this time to cancel searching driver from Windows Update, and then click Next to continue.6. Toggle Install from
3-8 Chapter 3: Driver installation7. Insert the SAS RAID card Support CD into the optical drive.8. Locate the driver in the corresponding folder of
ASUS PIKE 2208 3-93. Click Load Driver.4. A message appears, reminding you to insert the installation media containing the driver of the SAS RAID ca
3-10 Chapter 3: Driver installation5. Locate the driver in the corresponding folder of the Support CD, and then click OK to continue.6. Select LSI M
ASUS PIKE 2208 3-114. Click the Driver tab on the top, then click Update Driver.3.3.2 After Windows® Server 2008 OS installationTo update the RAID c
viii
3-12 Chapter 3: Driver installation5. Click Browse my computer for driver software.9. The system automatically updates the driver. After completing
ASUS PIKE 2208 3-133.4 Red Hat® Enterprise Linux OS 5 Driver InstallationTo install the RAID card driver when installing Red Hat Red Hat® Enterprise
3-14 Chapter 3: Driver installation5. When asked if you will load additional RAID controller drivers, select No, then press <Enter>.7. Follow
ASUS PIKE 2208 3-153.5 SUSE® Linux OS 11 Driver InstallationTo install the RAID card driver when installing SUSE Linux Enterprise Server OS: SUSE Lin
3-16 Chapter 3: Driver installation
ASUS contact informationASUSTeK COMPUTER INC.Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259Telephone +886-2-2894-3447Fax +886-2-2890-
EC Declaration of Conformity We, the undersigned, Manufacturer: ASUSTek COMPUTER INC. Address, City: No. 150, LI-TE RD., PEITOU, TAIPEI 112, TAIWAN R.
1Chapter 1: Product introductionThis chapter offers the PIKE 2208 SAS RAID card features and the new technologies it supports.
Komentáře k této Příručce