Asus ASMB5-iKVM Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Asus ASMB5-iKVM. Asus ASMB5-iKVM User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 88
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - ASMB5-iKVM

ASMB5-iKVMServer Management Board

Strany 2 - March 2011

xTypographyBold text Indicates a menu or an item to select.Italics Used to emphasize a word or a phrase.<Key> Keys enclosed in the less-th

Strany 3 - Contents

xiASMB5-iKVM specications summaryChipset Aspeed 2050Internal RAM 112 MB for system 16 MB for videoInternal ROM 16 MBTimers 32-bit Watchdog TimerMain

Strany 5

1Chapter 1: Product introductionThis chapter describes the server management board features and the new technologies it supports.

Strany 6

1-2 Chapter 1: Product introduction1.1 Welcome!Thank you for buying an ASUS® ASMB5-iKVM server management board!The ASUS ASMB5-iKVM is an Intelligent

Strany 7

ASUS ASMB5-iKVM 1-31.3 Features1. IPMI 2.0• System interface (KCS)• LAN interface (support RMCP+)• System Event Log (SEL)• Sensor Data Record (S

Strany 8 - Safety information

1-4 Chapter 1: Product introduction1.4 System requirementsBefore you install the ASMB5-iKVM board, check if the remote server system meets the follow

Strany 9 - About this guide

ASUS ASMB5-iKVM 1-51.5 Network setupThe ASMB5-iKVM server management board installed on the remote server connects to a local/central server via dire

Strany 10 - Typography

1-6 Chapter 1: Product introduction

Strany 11

2Chapter 2: InstallationThis chapter provides instructions on how to install the board to the server system and install the utilities that the board

Strany 12

iiE6569Second Edition V2 March 2011Copyright © 2011 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and softw

Strany 13 - Chapter 1: Product

2-2 Chapter 2: Installation2.2 Hardware installationTo install the server management board:1. Remove the remote server system cover, and then locate

Strany 14 - 1.2 Package contents

ASUS ASMB5-iKVM 2-34. When installed, the board appears as shown.5. Reinstall the remote server system cover, then connect the power plug to a groun

Strany 15 - 1.3 Features

2-4 Chapter 2: Installation2.3 Firmware update and IP congurationYou need to update the ASMB5-iKVM rmware and congure IP source before you start u

Strany 16 - 1.4 System requirements

ASUS ASMB5-iKVM 2-57. When the update process is completed, the following screen appears.When the update process is completed, the following screen a

Strany 17 - 1.5 Network setup

2-6 Chapter 2: Installation2.3.2 Congure BMC IP source static IP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu app

Strany 18

ASUS ASMB5-iKVM 2-72.3.3 Congure BMC IP source DHCP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu appears. Select

Strany 19 - Chapter 2: Installation

2-8 Chapter 2: Installation2.4 BIOS congurationYou need to adjust the settings in the BIOS setup of the remote server for correct conguration and c

Strany 20 - 2.1 Before you proceed

ASUS ASMB5-iKVM 2-9Configuration Source [Do Nothing]Allows you to select the IP address source type. Set the LAN channel parameters statically or dyna

Strany 21 - ASUS ASMB5-iKVM 2-3

2-10 Chapter 2: Installation2.4.3 System Event LogAllows you to view all the events in the BMC event log. It will take a maximum of 15 seconds to rea

Strany 22 - 2.3.1 Firmware update

ASUS ASMB5-iKVM 2-112.5 Running the ASMC5 utilityThe ASMC5 utility allows you to update the ASMB5-iKVM rmware, congure the LAN setting for the remo

Strany 23 - ASUS ASMB5-iKVM 2-5

iiiContentsNotices ... viSafety information ...

Strany 24 - No Yes

2-12 Chapter 2: InstallationASMC5 Help Menu optionsOptions Description-kcs[smic/bt/pci_smic] NetFn command data...Send IPMI command-bmc_ip_source sou

Strany 25 - ASUS ASMB5-iKVM 2-7

ASUS ASMB5-iKVM 2-132.5.1 Conguring the LAN controllerBefore you can establish connection to the ASMB5-iKVM board, you must congure the LAN port fo

Strany 26 - 2.4 BIOS conguration

2-14 Chapter 2: Installation2.5.2 Conguring the user name and passwordYou may change your user name and password from the ASMC5 utility.To change th

Strany 27

ASUS ASMB5-iKVM 2-152.6 Software installationYou can monitor, control, or manage the remote server from the local/central server using the ASUS Remot

Strany 28 - 2.4.3 System Event Log

2-16 Chapter 2: Installation3. Follow the installation wizard instructions to install the utility.2.6.2 Launching ARCTo launch the ARC utility, clic

Strany 29 - ASUS ASMB5-iKVM 2-11

3Chapter 3: ASUS Remote ConsoleThis chapter tells you how to use the ASUS Remote Console (ARC) that the server management board supports.

Strany 30 - ASMC5 Help Menu options

3-2 Chapter 3: ASUS Remote Console3.1 ASUS Remote Console (ARC)The ASUS Remote Console (ARC) is a web-based utility, designed for ASMB5-SOL PLUS, tha

Strany 31 - OS to check

ASUS ASMB5-iKVM 3-33.1.1 ARC sectionsMenu barThe Menu bar contains all the commands for the ARC application. Click on a menu to display a list of ava

Strany 32 - 2-14 Chapter 2: Installation

3-4 Chapter 3: ASUS Remote ConsoleSome remote server information (such as the SDR) contains several sensor groups such as Temperature, Voltage, and Fa

Strany 33 - 2.6 Software installation

ASUS ASMB5-iKVM 3-5Event windowThe Event window displays the Platform Event Trap (PET) received by the ARC. The PET information includes the event ind

Strany 34 - 2.6.2 Launching ARC

ivContents3.1.5 Displaying system event logs ...3-113.1.6 Using Remote Console ...

Strany 35 - Remote Console

3-6 Chapter 3: ASUS Remote Console3.1.2 Connecting to the remote serverTo connect to the remote server:1. From the menu bar, click Server, then sele

Strany 36

ASUS ASMB5-iKVM 3-7 The navigation window displays the remote server. The available remote server information are displayed on the Detail/SEL window.

Strany 37 - P8B-E/4L

3-8 Chapter 3: ASUS Remote Console3.1.3 Retrieving sensor informationThe Sensor Data Record (SDR) provides remote server system information through a

Strany 38

ASUS ASMB5-iKVM 3-93. Click More. A sensor window appears displaying additional information on the sensor. The Information tab displays basic sensor

Strany 39 - Detail/SEL window

3-10 Chapter 3: ASUS Remote Console3.1.4 Displaying FRU informationThe Field Replaceable Unit (FRU) information provides the manufacturer, product na

Strany 40

ASUS ASMB5-iKVM 3-113.1.5 Displaying system event logsThe System Event Log (SEL) is a non-volatile storage area where all remote server system events

Strany 41

3-12 Chapter 3: ASUS Remote Console3.1.6 Using Remote ConsoleThe Remote Console feature lets you see the remote server screen (text only) and is usef

Strany 42

ASUS ASMB5-iKVM 3-133.1.7 Displaying all remote server sensorsTo display all remote server sensors in graphical format:1. From the navigation window

Strany 43 - ASUS ASMB5-iKVM 3-9

3-14 Chapter 3: ASUS Remote Console3.1.8 Adjusting the monitoring settingsThe ARC application allows you to adjust the remote server monitoring setti

Strany 44

ASUS ASMB5-iKVM 3-15Enabling the Short Message Service (SMS) featureThe Short Message Service or SMS feature allows you to receive Platform Event Trap

Strany 45

vContents4.4.11 Date/Time/NTP Settings ...4-114.5 Remote Control ...

Strany 46

3-16 Chapter 3: ASUS Remote Console3.1.9 Controlling the remote server powerARC allows you to power up, power down, or reset the remote server using

Strany 47

ASUS ASMB5-iKVM 3-173.1.10 Viewing PET informationThe Platform Event Trap or PET is an SNMP trap used for system management alerts. When the ARC rece

Strany 48

3-18 Chapter 3: ASUS Remote Console4. Double-click Management and Monitoring Tools.5. Select Simple Network Management Protocol (SNMP).6. Click O

Strany 49

ASUS ASMB5-iKVM 3-19Important notice for Windows® XP (Service Pack 2) usersIf the local server system is behind a rewall, you must create a UDP port

Strany 50 - Power Down

3-20 Chapter 3: ASUS Remote Console3.2 ASUS Host Management Controller SetupThe ASUS Host Management Controller Setup utility provides precise congu

Strany 51 - PET information

ASUS ASMB5-iKVM 3-213.2.2 Command eldsThe utility menu bar has ve commands: Initial, View, Set, Monitor and Help. You can select a command using th

Strany 52 - 6. Click OK

3-22 Chapter 3: ASUS Remote ConsoleTo view the System Event Log (SEL):1. Select BMC SEL from the View command option, then press <Enter>. A com

Strany 53 - XP (Service Pack 2) users

ASUS ASMB5-iKVM 3-23To view the System Data Record (SDR):1. Select BMC SDR from the View command option, then press <Enter>. A complete list of

Strany 54 - Controller Setup utility

3-24 Chapter 3: ASUS Remote Console3.2.5 SetThe Set command controls the host interface type and the correct BMC time.To view the BMC information:1.

Strany 55 - 3.2.3 Initial

ASUS ASMB5-iKVM 3-25You can select from the following interfaces:KCS Interface - Keyboard Controller StyleSMIC Interface - Server Management Inter

Strany 56

viNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two cond

Strany 57 - ASUS ASMB5-iKVM 3-23

3-26 Chapter 3: ASUS Remote Console3.2.6 MonitorThe Monitor command displays real-time data on the remote server system and CPU temperatures, voltage

Strany 58 - 3.2.5 Set

ASUS ASMB5-iKVM 3-273.2.7 HelpThe Help command displays the available utility options, utility version, and copyright information.ASUS Host Managemen

Strany 59 - To select the host interface:

3-28 Chapter 3: ASUS Remote Console

Strany 60 - 3.2.6 Monitor

4Web-based user interfaceThis chapter tells you how to use the web-based user interface that the server management board supports.

Strany 61 - 3.2.7 Help

4-2 Chapter 4: Web-based user interface4.1 Web-based user interfaceThe web-based user interface allows you to easily monitor the remote server’s hard

Strany 62

ASUS ASMB5-iKVM 4-34.1.2 Using the utilityThe web-based graphics user interface displays when you login in the utility successfully.1. Menu bar: Cli

Strany 63 - Web-based

4-4 Chapter 4: Web-based user interface4.2 System InformationThis section contains the general information about the system, such as rmware version

Strany 64 - 4.1 Web-based user interface

ASUS ASMB5-iKVM 4-54.3.1 Sensor Readings (with Thresholds)The Sensor Readings page displays the system sensor information, including readings and sta

Strany 65 - 4.1.2 Using the utility

4-6 Chapter 4: Web-based user interface4.4 CongurationThis section allows you to congure the system settings. Click each function key to start usin

Strany 66 - 4.3 Server Health

ASUS ASMB5-iKVM 4-74.4.2 PEFThe PEF page allows you to modify the PEF conguration.11. Modify: Click to select the PEF item that you want to modify.

Strany 67 - 4.3.2 Event Log

viiREACHComplying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we published the chemic

Strany 68 - 4.4 Conguration

4-8 Chapter 4: Web-based user interface4.4.4 NetworkThe Network page allows you to congure the network settings.1. MAC Address: Select whether to

Strany 69 - 4.4.3 Mouse Mode

ASUS ASMB5-iKVM 4-94.4.6 SSLThe SSL page displays the default certicate and private key, and allows you to upload the new SSL certicate. Click Brow

Strany 70 - 4.4.5 SMTP

4-10 Chapter 4: Web-based user interface4.4.9 Congure LDAPThe Congure LDAP page allows you to authenticate and access the LDAP server. Complete the

Strany 71 - 4.4.7 Users

ASUS ASMB5-iKVM 4-114.4.11 Date/Time/NTP SettingsThe Date/Time/NTP Settings page allows you to set up specic date/time or synchronize the date/time

Strany 72 - 4.4.8 Remote Session

4-12 Chapter 4: Web-based user interface4.5 Remote ControlThis section allows you to perform remote operations on the server. Click each function key

Strany 73 - ASUS ASMB5-iKVM 4-11

ASUS ASMB5-iKVM 4-134.5.2 Server Power ControlThe Server Power Control page displays the current server power status and allows you to change the cur

Strany 74 - 4.5 Remote Control

4-14 Chapter 4: Web-based user interface4.5.4 Chassis Identify CommandThe Chassis Identify Command page allows you to perform a chassis identify comm

Strany 75 - 4.5.3 Capture Screen Video

ASUS ASMB5-iKVM 4-154.6 MaintenanceThis section allows you to perform the rmware update for the remote server. Click Enter Update Mode to open the 

Strany 76 - 4.5.5 Power Button

4-16 Chapter 4: Web-based user interface

Strany 77 - 4.7 Languages

AAppendix: Reference informationThe Appendix shows the location of the LAN ports for server management and BMC connector on server motherboards. This

Strany 78

viiiSafety informationElectrical safety• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating t

Strany 79 - Appendix: Reference

A-2 Appendix: Reference informationA.1 BMC connectorThe ASUS server motherboards that support the ASMB5-iKVM comes with a Baseboard Management Contro

Strany 80 - A.1 BMC connector

ASUS ASMB5-iKVM A-3A.2 LAN ports for server managementThe ASUS server motherboards that support the ASMB5-iKVM comes with three LAN (RJ-45) ports: on

Strany 81 - ASUS ASMB5-iKVM A-3

A-4 Appendix: Reference informationA.3 TroubleshootingProblem SolutionThe local/central server cannot connect to the ASMB5-iKVM board1. Check if the

Strany 82 - A.3 Troubleshooting

ASUS ASMB5-iKVM A-5A.4 BMC Sensor Codes TableCategory 1: Memory relatedSensor No.Sensor Name Sensor Type Sensor Type codeSensor Value or Event Type E

Strany 83 - A.4 BMC Sensor Codes Table

A-6 Appendix: Reference informationCategory 2: HDD / Backplane relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type0x

Strany 84

ASUS ASMB5-iKVM A-7Category 3: Power Supply relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type0x81 PSU1 Temp Temp

Strany 85 - ASUS ASMB5-iKVM A-7

A-8 Appendix: Reference informationCategory 4: Hardware Monitor / System Sensor relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Valu

Strany 86

ASUS ASMB5-iKVM A-90x3F P2VTT (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system) Voltage 0x02 Threshold(0x01) Lower

Strany 87 - ASUS ASMB5-iKVM A-9

A-10 Appendix: Reference information0xA2 FRNT_FAN1 FAN 0x04 Threshold(0x01) Lower Non-critical - going low Lower Critital - going low0xA3 FRNT_FA

Strany 88

ixAbout this guideThis user guide contains the information you need when installing and conguring the server management board.How this guide is organ

Komentáře k této Příručce

Žádné komentáře